top of page

LUBRICATION AUTOMATIONS

Siviera ribaltabile

plants and products for foundries

FILTERING SYSTEM

GLYCOL WATER

impianto filtraggio acqua glicole.jpg

FEATURES:

​

  • Flow rate 40 Lt / H

  • Cast iron pump

  • 380 Volt three phase

  • Motor HP1.5 Kw1.1

  • Dimensions 1200x60x40 mm

  • Weight kg. 71

FLOW LANCE WITH TROLLEY

(for salts in powder and granules)

lancia flussi.jpg
lancia flussi 1.jpg

TECHNICAL FEATURES:

​

  • Air connection 5/8 bar;

  • Auto dosage;

  • Container capacity kg.15;

  • At the end of the operation, lift the suction pipe to empty the system

WATER MIXING SYSTEMS - RELEASE AGENT

Fully automatic system "BIG model".

​

Ideal for centralized plant in the foundry for 6-8 presses.

TECHNICAL FEATURES:

​

  • Volumetric dosing pump scale 0,5-4% (max 1,500 liters / hour);

  • Accumulator tank 300 liters;

  • Self-priming 220 volt electric filling pump;

  • 24 volt solenoid valve by-pass button;

  • water-release agent mixing

  • Release agent

miscelazione acqua distaccante.jpg

PNEUMATIC SYSTEM WITH 1-2 NOZZLES

PISTON LUBRICATION

impianto pneumatico lubrifica pistoni.jp
impianto pneumatico lubrifica pistoni2.j

INSTRUCTIONS FOR USE:

​

  • 1. Connect compressed air min.4 Bar - max 8 Bar.

  • 2. Connect the 24 DC press consent.

  • 3. Position a nozzle at 100 mm from the piston and a nozzle over the spill hole of the container at a distance of 100 mm in a position that does not bother the pouring of the aluminum.

  • 4. If you intend to use only one nozzle, just turn the piston clockwise as far as it will go; this stops pumping and dispensing.

  • 5. Turn the manual consent screw positioned on the solenoid valve, the piston will start pumping, as soon as the oil comes out, replace the screw in the initial position.

  • 6. Set on the press panel "time lubricates piston" with 2 nozzles:

"1 second (for Pistons up to diam. 080)"

"1.5 seconds (for pistons up to diam. 100)"

"2 seconds (for Pistons up to diam. 120)"

"2,5 seconds (for Pistons up to diam. 140)"

​

If the single-nozzle system is used, of course, the setting time must be doubled; these quantities are indicative (in our table).

​

This quantity may vary based on the state of wear of the container and the piston and the hourly blows of the press, the injection speed, etc. and the type of lubricant used.

​

​

  • 7. IMPORTANT To adjust the quantity of oil, act only on "time lubricates piston" on the press panel, NEVER touch the frequency meter or anything else inside the system, this is already calibrated by our technician.

  • 8. The system can dose the oil by drop or by spraying, with a regulator positioned under the piston indicated with the words: Screw open> spray - Screw closed> drop.

  • 9. When loading the oil into the tank, never remove the filter, because the entry of foreign bodies could block the pump, since this has very small passages.

  • 10. The system is supplied with a visual oil lack alarm. When the light comes on, there is autonomy for about 60 minutes.

bottom of page